Roof detail pitched roof to high wall.
Pitched roof flashing detail.
Each soaker extends 100mm over the tile and 75mm up the wall.
Protect the eave from ice dams and sideways rain step one in steep slope roofing is the edge flashing.
Section 4 roof wall intersections build supplement flashings 81 roof junction detail getting flashings right between a tight area such as the main gable of a building and the ridge of a smaller gable can be difficult.
One common method is to lay the edge metal under the eaves membrane and over the rake.
Two ways to flash roof edges.
Above the roof a series of short masonry flashing components4 are mechanically fastened to the backup wall using a termination bar with continuous sealant5 along the top.
The soaker upstands are covered using a step flashing as described earlier.
These systems rely on overlapping elements roofing felts shingles tiles and flashing details to redirect the rainfall.
These short pieces of masonry flashings terminate outside the face of the masonry with a drip edge that also.
Details concrete masonry roofing wrb flashing.
The veneer is supported below the roof by cmu or other supporting structure.
With these installation pointers you can make sure this junction is weathertight.
Gibraltar drip edge flashing can be used with asphalt shingles or metal roofing panels.
This drip edge flashing provides protection from water damage along the eaves and rake of a roof.
Flashing joints are lapped 6 in the direction of water flow.
Horizontal flashings should provide weathering to a minimum of 75mm above the intersection with the roof.
The flashing extends up the wall at least 4.
The metal flashing is formed with a hook edge and cleated on 12 centers.
The flashing extends onto the roof a minimum of 2 inches 4 inches is preferable in more severe climate areas.
This detail illustrates a sloped roof terminating into a higher masonry veneer wall.
Stepped flashing is used where a sloped shingled roof intersects a vertical wall.
Cad details document name pdf dwg download all cad construction details 37 1 mb 3 4 mb mc01 identification of roof areas 694 kb 167 kb mc01a single layer underlayment 678 kb 302 kb mc01b double layer underlayment 711 kb 322 kb mc02 vent pipe flashing 626 kb 349 kb mc03 valley.
Step flashings are interwoven with the shingles and act essentially as shingles with an upturned leg to allow a transition of the vertical drainage plane of the wall to the drainage plane of the roof.
Variations to common side abutment details the traditional material for step and cover flashings secret gutter and soakers is lead usually code 4 or code 5 for exposed flashings and code 3 for soakers.